18 research outputs found

    Integration of electronic systems on wearable textile antenna platforms

    Get PDF

    Correlated shadowing and fading characterization of MIMO off-body channels by means of multiple autonomous on-body nodes

    Get PDF
    In off-body communication systems low-cost and compact transceivers are important for realistic applications. An autonomous off-body wireless node was designed and integrated onto a textile antenna. Channel measurements were performed for an indoor non line-off-sight 4x2 MIMO (Multiple-Input Multiple-Output) link using four off-body transmitting nodes and two similar fixed receiving nodes. The channel behavior is characterized as Rayleigh fading with lognormal shadowing and is fitted to a model determining fading and shadowing correlation matrices. The physics of the propagation is captured accurately by the model which is further used to simulate a link using diversity by means of Selection Combining, as implemented on the wireless nodes. The performance of measured and simulated links is compared in terms of outage probability level. The measurements and analysis confirm that the correlated shadowing and fading model is relevant for realistic off-body networks employing diversity by means of Selection Combining

    Energy-efficient off-body communication nodes with receive diversity

    Get PDF
    Off-body wireless communication applications range from fall-detection systems for the elderly to monitoring networks for rescue workers. Further development of practical body-worn systems requires compact, low-cost and low-power battery-powered equipment. A versatile wearable network node offering all these features, including a powerful microcontroller for data processing and additional memory for local data logging was designed and implemented. The node allows receive diversity, mitigating the negative impact of fading, which is typically present in indoor propagation environments. Channel measurements are performed for an indoor Non Line-of-Sight communication between two nodes. Mobile-to-base-station as well as mobile-to-mobile links are considered. A statistical analysis of the performance determines outage probability with and without receiver diversity for both link types, showing a significant diversity gain in all cases. Correlation properties, level crossing rate and average fade duration are also determined

    Flexible dual-diversity wearable wireless node integrated on a dual-polarised textile patch antenna

    Get PDF
    A new textile wearable wireless node, for operation in the 2.45 GHz industrial, scientific and medical (ISM) band, is proposed. It consists of a dual-polarised textile patch antenna with integrated microcontroller, sensor, memory and transceiver with receive diversity. Integrated into a garment, the flexible unit may serve for fall detection, as well as for patient or rescue-worker monitoring. Fragile and lossy interconnections are eliminated. They are replaced by very short radiofrequency signal paths in the antenna feed plane, reducing electromagnetic compatibility and signal integrity problems. The compact and flexible module combines sensing and wireless channel monitoring functionality with reliable and energy-efficient off-body wireless communication capability, by fully exploiting dual polarisation diversity. By integrating a battery, a fully autonomous and flexible system is obtained. This novel textile wireless node was validated, both in flat and bent state, in the anechoic chamber, assessing the characteristics of the integrated system in free-space conditions. Moreover, its performance was verified in various real-world conditions, integrated into a firefighter garment, and used as an autonomous body-centric measurement device

    Synchronous wearable wireless body sensor network composed of autonomous textile nodes

    Get PDF
    A novel, fully-autonomous, wearable, wireless sensor network is presented, where each flexible textile node performs cooperative synchronous acquisition and distributed event detection. Computationally efficient situational-awareness algorithms are implemented on the low-power microcontroller present on each flexible node. The detected events are wirelessly transmitted to a base station, directly, as well as forwarded by other on-body nodes. For each node, a dual-polarized textile patch antenna serves as a platform for the flexible electronic circuitry. Therefore, the system is particularly suitable for comfortable and unobtrusive integration into garments. In the meantime, polarization diversity can be exploited to improve the reliability and energy-efficiency of the wireless transmission. Extensive experiments in realistic conditions have demonstrated that this new autonomous, body-centric, textile-antenna, wireless sensor network is able to correctly detect different operating conditions of a firefighter during an intervention. By relying on four network nodes integrated into the protective garment, this functionality is implemented locally, on the body, and in real time. In addition, the received sensor data are reliably transferred to a central access point at the command post, for more detailed and more comprehensive real-time visualization. This information provides coordinators and commanders with situational awareness of the entire rescue operation. A statistical analysis of measured on-body node-to-node, as well as off-body person-to-person channels is included, confirming the reliability of the communication system

    Compact personal distributed wearable exposimeter

    Get PDF
    A compact wearable personal distributed exposimeter (PDE) is proposed, sensing the power density of incident radio frequency (RF) fields on the body of a human. In contrast to current commercial exposimeters, our PDE, being composed of multiple compact personal wearable RF exposimeter sensor modules, minimizes uncertainties caused by the proximity of the body, the specific antenna used, and the exact position of the exposimeter. For unobtrusive deployment inside a jacket, each individual exposimeter sensor module is specifically implemented on the feedplane of a textile patch antenna. The new wearable sensor module's high-resolution logarithmic detector logs RF signal levels. Next, on-board flash memory records minimum, maximum, and average exposure data over a time span of more than two weeks, at a one-second sample period. Sample-level synchronization of each individual exposimeter sensor module enables combining of measurements collected by different nodes. The system is first calibrated in an anechoic chamber, and then compared with a commercially available single-unit exposimeter. Next, the PDE is validated in realistic conditions, by measuring the average RF power density on a human during a walk in an urban environment and comparing the results to spectrum analyzer measurements with a calibrated antenna

    Whole-body averaged specific absorption rate estimation using a personal, distributed exposimeter

    Get PDF
    For the first time, a body area network (BAN) is used to construct a personal, distributed exposimeter (PDE), which can measure the whole-body averaged specific absorption rate (SAR(wb)) in real life, together with the incident power density (S-inc). The BAN consists of four textile antennas with integrated radio frequency receiver nodes tuned to the Global System for Mobile Communications (GSM) 900 downlink band. Calibration measurements at 942.5 MHz, using a human subject, are performed in an anechoic chamber. These are combined with numerical simulations to estimate both SAR(wb) and S-inc from the averaged received power on the PDE. The PDE has 50% prediction intervals of 3 dB on S-inc and 3.3 dB on the SAR(wb), caused by the presence of the human body, whereas the best single textile antenna in our measurements exhibits PI50's of 7.1 dB on S-inc and 5 dB on SAR(wb). Measurements using the PDE are carried out in Ghent, Belgium, during which a median S-inc = 47 mu W/m(2) and SAR(wb) = 0.25 mu W/kg are measured

    A personal, distributed exposimeter: procedure for design, calibration, validation, and application

    Get PDF
    This paper describes, for the first time, the procedure for the full design, calibration, uncertainty analysis, and practical application of a personal, distributed exposimeter (PDE) for the detection of personal exposure in the Global System for Mobile Communications (GSM) downlink (DL) band around 900 MHz (GSM 900 DL). The PDE is a sensor that consists of several body-worn antennas. The on-body location of these antennas is investigated using numerical simulations and calibration measurements in an anechoic chamber. The calibration measurements and the simulations result in a design (or on-body setup) of the PDE. This is used for validation measurements and indoor radio frequency (RF) exposure measurements in Ghent, Belgium. The main achievements of this paper are: first, the demonstration, using both measurements and simulations, that a PDE consisting of multiple on-body textile antennas will have a lower measurement uncertainty for personal RF exposure than existing on-body sensors; second, a validation of the PDE, which proves that the device correctly estimates the incident power densities; and third, a demonstration of the usability of the PDE for real exposure assessment measurements. To this aim, the validated PDE is used for indoor measurements in a residential building in Ghent, Belgium, which yield an average incident power density of 0.018 mW/m(2)
    corecore